The systems are controlled with a Windows application
that allows operators to set up parameters for a load board and then click
to start a run.
Run duration is then timed automatically and the operator is notified when
it is time to remove a load board. Forward voltage and temperature
measurements are collected during the test and logged along with any
anomalies that are detected. The software supports the following Joint
Electron Device Engineering Council (JEDEC) protocols and others:
- Room Temperature Operating Life Test (RTOL)
- High Temperature Operating Life Test (HTOL)
- Wet High Temperature Operating Life Test (WHTOL)
- Low Temperature Operating Life Test (LTOL)
- Power Forward Temperature Cycling

LED Stress Testing System
For
more information please contact:
Sales, (858)558-8282 option 6